subject: Fire creator: Amit H. Varma, 0000-0001-7153-4681
10.4231/R7DZ067N
Amit H. Varma , Erica C. Fischer , Qiaqia Zhu
10/14/2014
These documents present test data and photographs from seven single-bolted lap joint tests conducted at ambient temperature, 400 deg C and 600 deg C, and comparisons of test results with results from benchmarked finite element analysis.
Bolted connections Civil Engineering Finite Element Analysis Fire High temperature tests Plate bearing
10.4231/R7NP22DD
06/23/2015
Four axially loaded steel columns were tested under non-uniform heating conditions to experimentally evaluate the thermal gradient effects on the fire resistance (temperature and failure time) of steel columns with pinned ends.
ASTM A992 Civil Engineering columns Experimental Tests Fire steel structures structural engineering thermal bowing
Display #