Datasets

subject: Fire

Total is 2 Results
Fire Behavior of Bearing Bolted Connections

10.4231/R7DZ067N

Amit H. Varma ORCID logo , Erica C. Fischer , Qiaqia Zhu

10/14/2014

These documents present test data and photographs from seven single-bolted lap joint tests conducted at ambient temperature, 400 deg C and 600 deg C, and comparisons of test results with results from benchmarked finite element analysis.

Bolted connections Civil Engineering Finite Element Analysis Fire High temperature tests Plate bearing

Thermal gradients in columns subjected to fire

10.4231/R7NP22DD

Amit H. Varma ORCID logo , Lisa Choe

06/23/2015

Four axially loaded steel columns were tested under non-uniform heating conditions to experimentally evaluate the thermal gradient effects on the fire resistance (temperature and failure time) of steel columns with pinned ends.

ASTM A992 Civil Engineering columns Experimental Tests Fire steel structures structural engineering thermal bowing

Display #

Results 1 - 2 of 2